19 mm 3 4 airspace between 50 mm 2 fire wall and wood framing 50 mm 2 h studs 610 mm 24 o c.
1 hour fire rated gypsum wall detail. Ss 104 1 hour partition to steel deck. Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm. To support the wall. Typical fire wall assembly sheetrock gypsum panels as required 50 x 100 mm 2 x 4 stud framing 25 4 mm 1 sheetrock gypsum liner panels min.
These listings are short summaries to serve as a. Type x gypsum board is wallboard to which non combustible fibers have been added. Access our all new collection of sound tested fire rated wall assemblies. Sw 106 1 hour shaftwall with deflection track.
Head of wall firestop system firestop sealant. National gypsum company fire and sound selector ul type designation product name 5 16 gold bondfsw brand fire shield gypsum board 5 8 gold bond brand fire shield gypsum board type x 5 8 gold bond brand fire shield exterior soffit board type x 5 8 gold bond brand hi abuse xp fire shield gypsum board type x 5 8 gold bond brand hi impact xp fire shield. Title ul design head of wall firestop system page. Ul design u499 w419.
According to the book commercial drafting and detailing a typical one hour fire rated wall consists of 2x4 studs spaced 16 inches from the center of one stud to the center of the next covered by 5 8 inch type x gypsum board. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. 1 hour partition at 1 hour exterior wall 1 hour partition at non rated exterior wall 54 55 gypsum board fire trak shadowline elastomeric spray firestop elastomeric spray firestop w414 w419 gypsum board fire trak shadowline v451 w419 sw 614 shaftwall framing at duct penetration detail no. 6 usg fire resistant assemblies test certification test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
References resources. 610 mm with 1 25 4 mm type s drywall screws 12 305 mm o c. Ul design u465 v438. Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
5 8 15 9 mm toughrock fireguard c gypsum board or 5 8 densarmor plus fireguard c gypsum panels applied perpendicular to resilient channels 24 o c. This allows the fire wall to remain intact protecting the adjacent townhouse. Head of wall firestop system gypsum board fire trak shadowline.